Satec EM920 Installation Manual User Manual

Browse online or download User Manual for Equipment Satec EM920 Installation Manual. SATEC EM920 Installation Manual User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1

EM920 POWER QUALITY AND REVENUE METER Installation Manual BG0481 Rev. A1

Page 2 - LIMITED WARRANTY

Chapter 4 Chapter 2 Installation The eXpertmeter™ EM920 Socket meter is designed to mount into a standard meter socket. Follow the Installation s

Page 3

Chapter 2 Installation 5 Mechanical Installation Refer to the figures provided in this section to properly perform the mechanical installation.

Page 4 - Table of Contents

Chapter 6 Physical Description Device Structure Figure 3: EM920 internal structure Optional Modules location Figure 4: EM920 internal structure

Page 5 - FIGURES

Chapter 2 Installation 7 Meter External connections Figure 5:Meter Base – rear view

Page 6

Chapter 8 Electrical Installation Before installing, ensure that all incoming power sources are shut OFF. Failure to observe this practice can re

Page 7 - Chapter 1 Introduction

Chapter 2 Installation 9 Figure 7: Four Wire WYE Connection No PTs Using 3CTs - Wiring Setup: 4Ln3 Figure 8:Four Wire WYE Connection Using 3 PTs

Page 8 - Chapter 1 Introduction

Chapter 10 Figure 9: Four Wire DELTA Connection Using no PTs and 3(4) CTs - Wiring Setup: 4LL3 Figure 10: Four Wire DELTA Connection Using 3 P

Page 9 - Socket Meter Overview

Chapter 2 Installation 11 Figure 11: Three Wire DELTA Connection Using no PTs and 2 CTs - Wiring Setup: 3OP3 Figure 12: Three Wire DELTA Connect

Page 10 - Chapter 2 Installation

Chapter 12 Input / Output ports options Before I/O Module installation ensure that all incoming power sources are shut OFF. Failure to observe t

Page 11 - Mechanical Installation

Chapter 2 Installation 13 Optional I/O modules 8DI The 8DI module consists of eight status inputs detection. To install the 8DI module follow instr

Page 12 - Physical Description

ii DANGER This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may constitute a risk of electric s

Page 13 - Meter External connections

Chapter 14 Relay Outputs (6RO – optional module) The 6RO module consists of: four FORM C (SSR) and two FORM A (EMR) relay outputs. To install the

Page 14 - Electrical Installation

Chapter 2 Installation 15 Figure 18: 4AO Connection It is recommended to connect unused Analog output channels to Common terminal. ⇒ The 4AO m

Page 15

Chapter 16 Communications options The EM920 has several communication alternatives depending on your ordering preferences. All communications por

Page 16

Chapter 2 Installation 17 USB Communication port (USB – on board) The EM920 provides a standard full speed USB DEVICE port. The USB DEVICE port co

Page 17

Chapter 18 To install the GSM/GPRS module follow instructions: 1) Remove the plastic cover 2) Remove the body shield 3) Plug-in the module in

Page 18 - Input / Output ports options

Chapter 2 Installation 19 Figure 23: ETHERNET module RS-485/232 Communication port (COM4 – ETH optional module) The RS-485/232 Communication port

Page 19 - Optional I/O modules

Chapter 20 RS-232 mode In the RS-232 mode, the 485/232 wire must be tied to GND wire as shown in figure 25 Figure 25: Serial Communication Conne

Page 20

Chapter 2 Installation 21 Auxiliary Power Supply AC/DC Auxiliary Power Supply The EM920 can be equipped with additional power supply to redundant t

Page 21

Chapter 22 Chapter 3 Communications 1. Communications Computer Connections – RS-232 Figure 28: RS-232 Simple 3-wire Connection , 25

Page 22 - Communications options

Appendix: Technical Specifications 23 Chapter 4 Replacing the Battery When the battery level drops below the minimum allowed threshold, the LCD gr

Page 23 - Optional Communication ports

iii relief to reduce mechanical strain on the screw terminals, if necessary. 6. Only qualified personnel familiar with the instrument and its associa

Page 24

Appendix: Technical Specifications 24 Appendix: Technical Specifications Inputs Ratings AC Voltage inputs Va, Vb, Vc and Vref - 50/60Hz High input

Page 25

Appendix: Technical Specifications 25 Power Supply Power supply Supplied from Monitored Voltage inputs Three Phase PS, Rated Inputs 50/60 Hz 57.7

Page 26

Appendix: Technical Specifications 26 SSR – 4 relays (FORM C) 0.15A @ 250V AC/DC Operation time Release time 1 ms 1 ms Insulation Dielectric with

Page 27 - Auxiliary Power Supply

Appendix: Technical Specifications 27 Communication ports COM1 Built-in Infra Red communication port DISPLAY unit RS232 communication, TTL level,

Page 28 - 1. Communications

Appendix: Technical Specifications 28 Protocols MODBUS RTU/ASCII and DNP3.0 USB connector Cable terminated with USB type A Input Isolation 2500

Page 29 - IMPORTANT

Appendix: Technical Specifications 29 Standards Compliance EMC ANSI C12.1 Reference: IEC 61000 Surge – IEEE C62.41.2-2002  100kHz ring wave 

Page 30 - Inputs Ratings

Appendix: Technical Specifications 30 Measurement Specifications Accuracy Parameter Full Scale @ Input Range % Reading % FS Conditions Range Voltag

Page 31 - Input/Output ports

Appendix: Technical Specifications 31 CT - primary current rating of external current transformer FSV - voltage full scale FSI - current full scale

Page 32

iv Table of Contents Chapter 1 Introduction... 1 About This Manual...

Page 33 - Communication ports

v FIGURES Figure 1: Front view - Nameplate description... 3 Figure 2: EM920 - FORM 9S Dimensions...

Page 34 - Construction

vi TABLES Table 1: Wiring Configuration... 8 Table 2: 4AO – Output Curent s

Page 35 - Standards Compliance

Chapter 1 Introduction 1 Chapter 1 Introduction About This Manual This manual is intended to assist the user in the installation of the eXpertmeter™

Page 36 - Measurement Specifications

2 Chapter 1 Introduction • Auxiliary power supply option – AC/DC and Low DC options are available • High resolution 4’ Graphic LCD display • Four

Page 37

Chapter 1 Introduction 3 Socket Meter Overview Figure 1: Front view - Nameplate description

Comments to this Manuals

No comments