Page view 164
Appendix E EN50160 Statistics Log Files
Series PM175 Powermeters
165
Field No.
Designation
Description
11
V2 N1 110%
Number of incidents u>120% on phase V2
12
V2 N2 150%
Number of incidents u>150% on phase V2
13
V2 N3 200%
Number of incidents u>200% on phase V2
14
V2 N4 250%
Number of incidents u>250% on phase V2
15
V2 N5 300%
Number of incidents u>300% on phase V2
16
V3 N1 110%
Number of incidents u>120% on phase V3
17
V3 N2 150%
Number of incidents u>150% on phase V3
18
V3 N3 200%
Number of incidents u>200% on phase V3
19
V3 N4 250%
Number of incidents u>250% on phase V3
20
V3 N5 300%
Number of incidents u>300% on phase V3
21
V1 Peak Max
Maximum peak voltage on phase V1
22
V2 Peak Max
Maximum peak voltage on phase V2
23
V3 Peak Max
Maximum peak voltage on phase V3
Supply Voltage Unbalance
1
Nnv
Number of non-valid 10-min intervals
2
N
Number of valid 10-min intervals
3
N1
Number of incidents V Unb > 2%, N1
4
N1/N, %
EN50160 compliance ratio, N1/N
5
V Unb% Max
Maximum voltage unbalance
Harmonic Voltage
1
Nnv
Number of non-valid 10-min intervals
2
N
Number of valid 10-min intervals
3
N1
Number of polyphase harmonic voltage incidents, N1
4
N2
Number of polyphase voltage THD incidents, N2
5
N1/N, %
EN50160 harmonic voltage compliance ratio, N1/N
6
N2/N, %
EN50160 voltage THD compliance ratio, N2/N
7
V1 N1
Number of harmonic voltage incidents on phase V1
8
V1 HD% Max
Worst-case harmonic magnitude on phase V1, %Un
9
V1 H#
Worst-case harmonic component number on phase V1
10
V1 N2
Number of voltage THD incidents on phase V1
11
V1 THD Max
Worst-case voltage THD on phase V1
12
V2 N1
Number of harmonic voltage incidents on phase V2
13
V2 HD% Max
Worst-case harmonic magnitude on phase V2, %Un
14
V2 H#
Worst-case harmonic component number on phase V2
15
V2 N2
Number of voltage THD incidents on phase V2
16
V2 THD Max
Worst-case voltage THD on phase V2
17
V3 N1
Number of harmonic voltage incidents on phase V3
18
V3 HD% Max
Worst-case harmonic magnitude on phase V3, %Un
19
V3 H#
Worst-case harmonic component number on phase V3
20
V3 N2
Number of voltage THD incidents on phase V3
21
V3 THD Max
Worst-case voltage THD on phase V3
Interharmonic Voltage
1
Nnv
Number of non-valid 10-min intervals
2
N
Number of valid 10-min intervals
3
N1
Number of polyphase interharmonic voltage incidents, N1
4
N2
Number of polyphase interharmonic THD incidents, N2
5
N1/N, %
EN50160 interharmonic voltage compliance ratio, N1/N
6
N2/N, %
EN50160 interharmonic voltage THD compliance ratio, N2/N
7
V1 N1
Number of interharmonic voltage incidents on phase V1
8
V1 HD% Max
Worst-case interharmonic magnitude on phase V1, %Un
9
V1 H#
Worst-case interharmonic component number on phase V1
10
V1 N2
Number of interharmonic voltage THD incidents on phase V1
11
V1 THD Max
Worst-case interharmonic voltage THD on phase V1
12
V2 N1
Number of interharmonic voltage incidents on phase V2
13
V2 HD% Max
Worst-case interharmonic magnitude on phase V2, %Un
14
V2 H#
Worst-case interharmonic component number on phase V2
15
V2 N2
Number of interharmonic voltage THD incidents on phase V2
16
V2 THD Max
Worst-case interharmonic voltage THD on phase V2
17
V3 N1
Number of interharmonic voltage incidents on phase V3
18
V3 HD% Max
Worst-case interharmonic magnitude on phase V3, %Un
19
V3 H#
Worst-case interharmonic component number on phase V3
20
V3 N2
Number of interharmonic voltage THD incidents on phase V3
21
V3 THD Max
Worst-case interharmonic THD on phase V3
Mains Signaling Voltage
1
Nnv
Number of non-valid 3-sec intervals
2
N
Number of valid 3-sec intervals
Page view 164